When facility processes include welding, effective fume collection and filtration are important to operational success and productivity. With the variety of welding techniques employed today, determining the ideal weld fume control method for your enterprise, can be a challenge. Should you use the source, ambient, or a combination of the two?
While both weld fume extraction approaches effectively filter air, in most situations, a source capture system is the first choice for collecting and controlling weld fume particulate. If overhead cranes or other conflicting conditions limit the suitability of source capture equipment, ambient control may be an effective alternative solution for weld fumes.
Before attempting to identify a weld fume extraction system for your organization, conduct a thorough review of your facility, processes, and worker requirements. This will help you better identify a weld fume extraction solution that meets your operation’s needs.
Production Materials
What types of materials are being welded?
Production Volume
What is the rate of fume generation? How many stations are active? Is welding consistent throughout the day or intermittent?
Work Cell Layouts
Is the area open or divided into individual cells?
Worker Movement
Is the welder stationary or moving around the item being welded?
Production Area
Are there physical space limitations due to structures or overhead cranes?
Welder Preference
Are workers willing to use a capture hood or a portable system?
Space Flexibility
Is it important to have the ability to rearrange work cells?
As its name implies, source capture means the weld fumes are collected at – or close to – their point of origin. With this setup, a close-capture weld fume hood is strategically placed to extract the weld fumes prior to it reaching the welder’s breathing zone, and well before weld fumes are dispersed and diluted throughout the air in the facility.
Source capture is widely considered the method of weld fume collection because it focuses on the fumes at their point of generation, utilizing smaller air volumes to control contaminants before they further circulate.
There are multiple means for effective source capture including stationary weld fume hoods, extraction arms, and downdraft benches. If the work performed in a specific area is consistent, a properly located fixed weld fume hood would be the ideal solution. If the area is used for different work or applications, a versatile extraction arm can offer valuable maneuverability. And if the weld requires movement around the source, a downdraft bench may be an appropriate option.
When properly designed and installed, source-capture weld fume extraction systems can effectively collect the fume produced in most industrial settings. Having a thorough understanding of the processes, contaminants, and working practices will help ensure performance expectations are met.
Unlike source capture, ambient control methods utilize the facility’s natural air movement to promote the filtration of the overall air volume in the facility, controlling average overall concentrations of weld fumes in a work area. Mitigation strategies that include ambient collection are intended to help process owners manage weld fumes in a facility by providing air exchanges at regular intervals.
Maintaining consistent and predictable air movement throughout the designated work zone is critical for effective ambient collection and filtration. Identifying airflow patterns in your operation using a visual modeling tool and imagery assists in collector placement throughout the facility.
Because weld fumes naturally rise — typically 10-15 feet above the shop floor — the air intake should be placed at that level. Returning filtered air near the floor level helps support the natural circulation in a facility.
Ambient collection may be an appropriate solution if weld stations or work areas in your facility are frequently altered to accommodate different projects. When utilizing an ambient weld fume extraction system, it’s common to have multiple in-take and exhaust locations. The number of collection points required for proper filtration is determined by the size of the work area, the rate or duration of welding, and the actual application or type of welding being conducted.
Regardless of the system you select, proper dust collection for weld fume management is only one aspect of your overall mitigation plan. As you initiate discussions about your facility’s unique weld fume mitigation strategies — and the viability of these distinct solutions — we recommend consulting a dust collection professional and your local Authority Having Jurisdiction.
Donaldson’s comprehensive dust control solutions help process owners effectively address their dust, fume, and mist collection challenges by providing knowledgeable guidance, industry-leading equipment as well as unrivaled aftermarket service and support.
Backed by more than 250,000 global installations over 50 years, and a select network of partners, no other manufacturer is more capable – or more trusted – to solve your dust, fume, and mist collection challenges than Donaldson. With our customer-inspired consultative, comprehensive and connected approach to dust, fume, and mist control, Donaldson is with you every step of the way.