Shop Contact

Recommended Replacement Schedule: Preventative Maintenance

As regulations and best practices become more stringent, it is important for manufacturing facilities to know the appropriate replacement schedule for elements that protect their process and product integrity. If a defined replacement schedule is not available for preventative maintenance of filtration elements, consider the following recommended replacement intervals.

Housing Replaceable Part Type Application Recommended Replacement Interval Steam Sterilization Cycles
3 MOS 6 MOS 12 MOS 5 YRS
DF P, B, V, M, S Compressed air        
A Compressed air      
AG, SG, HD PE, SB, FF, MF, SMF, FFHTNX, MFHTNX, SMFHTNX Compressed air

       
AK Compressed air
       
PEP, SBP, FFP, MFP, SMFP Compressed air
       
Drains UFM-D, UFM-T, UFM-P Condensate management        
P-EG, PG-EG, P-BE P-SRF V, P SRF X*, PF-PT N Sterile air, gas       Up to 150 cycles
*Up to 250 cycles
P-GS, P-GSL N Steam, gas       Or after 6 cleanings
P-KG, P-FG, P-PT PP-FC, PP-FC 100 Liquid        
PP N, PP100 N, PP-TF N Liquid        
PF-EG, PG-IL PES WN, PES BN Liquid       Up to 100 cycles
P-GSL N Liquid       Or 6 ultrasonic baths
PG-EG, P-EG PF-PT N, P-PE, P-FF, P-MF, P-SMF, P-SB Compressed air, gas        
P-AK Gas        
PP N, PP100 N, PP-TF N Gas        
Ultrapac™ Smart DF-S Ultrapleat (pre- and post-filter) Compressed Air Every 3 months, check integrity with mobile app or dryer screen for element status
Desiccant cartridges
UltraSilencer
Ultrapac™ 2000 DF-S Ultrapleat Compressed air Every 3 months, check integrity with dryer screen for element status
Desiccant cartridges
Gaskets Gaskets Gasket At least every year or with every element replacement

Have more questions about how our products benefit your business?

Important Notice 
Many factors beyond the control of Donaldson can affect the use and performance of Donaldson products in a particular application, including the conditions under which the product is used. Since these factors are uniquely within the user's knowledge and control, it is essential the user evaluate the products to determine whether the product is fit for the particular purpose and suitable for the user's application. All products, specifications, availability and data are subject to change without notice, and may vary by region or country.

Close